Arch. cardiol. Méx ; 93(4): 391-397, Oct.-Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527715

ABSTRACT

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

2.
Gac. méd. Méx ; 158(6): 380-386, nov.-dic. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430367

ABSTRACT

Resumen Introducción: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. Objetivo: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. Métodos: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. Resultados: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. Conclusiones: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Abstract Introduction: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. Objective: To evaluate the safety and efficacy of the of the National Institute of Cardiology (INC) bioprosthetic heart alve of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. Methods: Single-center study that ncluded 341 patients who underwent single surgical aortic valve replacement with INC heart valve. Results: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. Conclusions: The INC heart valve is efficacious and safe, and is associated with a The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.

3.
Arch. cardiol. Méx ; 92(3): 334-341, jul.-sep. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1393828

ABSTRACT

Abstract Objective: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. Methods: Two polymorphisms of the CETP gene [−971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. Results: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the −971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). Conclusion: This study demonstrates that CETP Taq1B A/G and CETP −971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


Resumen Objetivo: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. Métodos: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. Resultados: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). Conclusión: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.

4.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Article in English | LILACS | ID: biblio-1249911

ABSTRACT

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Subject(s)
Animals , Male , Female , Rabbits , Paclitaxel/administration & dosage , Sirolimus/administration & dosage , Drug-Eluting Stents , Prosthesis Design , Spectrophotometry, Infrared , Swine , Follow-Up Studies , Disease Models, Animal , Microscopy
5.
Arch. cardiol. Méx ; 90(2): 142-147, Apr.-Jun. 2020. graf
Article in English | LILACS | ID: biblio-1131023

ABSTRACT

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Subject(s)
Humans , Animals , Dogs , Rabbits , Prosthesis Design , Stents , Coronary Vessels/surgery , Coronary Artery Disease/surgery , Fluoroscopy , Chromium Alloys/chemistry , Models, Animal
6.
Rev. invest. clín ; 72(1): 19-24, Jan.-Feb. 2020. tab
Article in English | LILACS | ID: biblio-1251830

ABSTRACT

ABSTRACT Background: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). Objective: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. Methods: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. Results: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. Conclusion: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , DEAD-box RNA Helicases/genetics , Acute Coronary Syndrome/genetics , Myocardial Infarction/genetics , Case-Control Studies , Lymphotoxin-alpha/genetics , Genetic Predisposition to Disease , Polymorphism, Single Nucleotide , Adaptor Proteins, Signal Transducing/genetics , Gene Frequency , Genotype , Mexico
7.
Rev. invest. clín ; 72(1): 32-36, Jan.-Feb. 2020. graf
Article in English | LILACS | ID: biblio-1251832

ABSTRACT

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged , Prosthesis Design , Stents , Myocardial Ischemia/surgery , Pilot Projects , Follow-Up Studies , Ultrasonography , Treatment Outcome , Myocardial Ischemia/physiopathology , Myocardial Ischemia/diagnostic imaging , Mexico
8.
Arch. cardiol. Méx ; 88(5): 432-440, dic. 2018. graf
Article in Spanish | LILACS | ID: biblio-1142153

ABSTRACT

Resumen Introducción: Un trombo intracorononario largo reclasificado es un predictor independiente de resultados adversos y no reflujo en el infarto agudo de miocardio con elevación del ST. Pacientes con mayor carga de trombo residual tienen peor disfunción microvascular y mayor daño miocárdico. Métodos: Evaluamos retrospectivamente a 833 pacientes que fueron a angioplastia primaria entre enero del 2011 y junio del 2016. La carga de trombo residual final fue reclasificada tras realizar el cruce de la guía, predilatación con balón o tromboaspiración, para restaurar y estabilizar un flujo TIMI 2-3. Las estrategias de stent diferido vs. stent inmediato fueron comparadas, siendo el objetivo primario la incidencia de no reflujo (TIMI ≤ 2, o TIMI 3 con TMP < 2). Resultados: Cuarenta y siete pacientes (6.8%) presentaron una alta carga trombo residual reclasificado. La coronaria derecha fue la arteria culpable en 34 casos. Hubo mayor frecuencia de ectasia coronaria en el grupo de stent diferido (p = 0.005). Se encontraron menores tasas de no reflujo en el stent diferido (36% vs. 58%), con una mayor frecuencia de un TMP 3 (p = 0.005). Tras la nueva cateterización un 56% quedó libre de stent en el grupo diferido y la anticoagulación oral les fue más frecuentemente indicada (p = 0.031). La tasa de eventos cardiacos adversos mayores fue similar entre los grupos. Hubo una tendencia a una mejor función ventricular izquierda en el grupo diferido (p = 0.056). Conclusiones: El stent diferido puede ser una alternativa eficiente en pacientes con IAM CEST y alta carga de trombo residual reclasificado, después de conseguir un flujo TIMI 2-3 estable.


Abstract Background: Reclassification of a large thrombus burden is an independent predictor of major adverse cardiac events and no-reflow in patients with ST- segment elevation myocardial infarction (STEMI). Patients with a greater residual thrombus burden have worse microvascular dysfunction and greater myocardial damage. Methods: A retrospective analysis was performed on 833 STEMI patients who underwent primary percutaneous coronary intervention. The final residual thrombus burden was reclassified after the lesion was wired, and a thrombus aspiration or balloon dilatation was performed to restore and stabilise a thrombolysis in myocardial infarction (TIMI) 2-3 flow. Deferred stenting (DEI) was compared with immediate stenting (ISI) group, and the primary outcome was the incidence of no-/slow-reflow (TIMI ≤ 2, or TIMI 3 with myocardial blush grade < 2). Results: Overall, 47 patients (6.8%) had a residual large thrombus burden reclassified. The right coronary artery was the culprit vessel in 34 cases. More patients had coronary ectasia in the DSI group (P=.005). Fewer patients in the DSI had no-/slow-reflow (36% vs. 58%), and the myocardial blush grade 3 was more frequent in the DSI group (P=.005). After repeat coronary angiography in the DSI group, stenting was not performed in 56%, and oral anticoagulation was more frequent in the follow-up (P=.031). Major cardiac adverse events were similar between groups. There was a tendency to better left ventricular function in the DSI group (P=.056). Conclusions: Deferred stenting may be an efficient option in STEMI patients with a residual large thrombus burden reclassified after achieving a stable TIMI 2-3 flow.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Coronary Thrombosis/therapy , Stents , Coronary Angiography/methods , Percutaneous Coronary Intervention/methods , ST Elevation Myocardial Infarction/therapy , Time Factors , Coronary Thrombosis/diagnostic imaging , Retrospective Studies , Follow-Up Studies , Longitudinal Studies , Ventricular Function, Left , Anticoagulants/administration & dosage
9.
Arch. cardiol. Méx ; 83(4): 257-262, oct.-dic. 2013. tab
Article in English | LILACS | ID: lil-703026

ABSTRACT

Objective: The objective of this study was to establish the role of the TLR-4 gene polymorphisms in individuals in risk of developing ACS. Methods: The study included 457 Mexican patients with ACS and 283 control individuals. The TLR-4 Asp299Gly and TLR-4 Thr399Ile single nucleotide polymorphisms were genotyped using 5' exonuclease TaqMan genotyping assays on an 7900HT Fast real-time PCR system according to manufacturer's instructions (Applied Biosystems, Foster City, USA). Results: The results obtained in this study showed that the frequency of the two polymorphisms (TLR-4 Asp299Gly and TLR-4 Thr399Ile) studied were similar between patients with ACS and healthy controls. Multiple logistic regression analysis showed that the largest risk factor for ACS development was given by smoking (11.88-fold increased risk), hypertension (4.32-fold increased risk), type II diabetes (3.44-fold increased risk), gender (2.32-fold increased risk), and dyslipidemia (1.52-fold increased risk). Conclusion: The Asp299Gly and Thr399Ile polymorphisms were not associated with susceptibility to ACS in the Mexican population.


Objetivo: El objetivo de este estudio fue establecer el papel de los polimorfismos del gen TLR-4 en individuos en riesgo de desarrollar síndrome coronario agudo (SCA). Métodos: El estudio incluyó a 457 pacientes mexicanos con SCA y 283 individuos como grupo control. Los polimorfismos de un solo nucleótido TLR-4 Asp299Gly y TLR-4 Thr399Ile fueron determinados usando ensayos TaqMan 5' exonucleasa en un equipo tiempo real 7900HT (Fast real-time PCR system) de acuerdo con instrucciones del fabricante Applied Biosystems, Foster City, EE.UU. Resultados: Los resultados obtenidos mostraron que las frecuencias de los 2 polimorfismos (TLR-4Asp299Gly y TLR-4 Thr399Ile) estudiados fueron similares entre pacientes con SCA e individuos control. No obstante, el análisis de regresión logística mostró que los factores de mayor riesgo para desarrollar SCA se debieron a tabaquismo (incrementa 11.88 veces el riesgo), hipertensión (incrementa 4.32 veces el riesgo), diabetes tipo 2 (incrementa 3.44 veces el riesgo), género (incrementa 2.32 veces el riesgo), y la dislipidemia (incrementa 1.52 veces el riesgo). Conclusión: Determinamos que los polimorfismos Asp299Gly y Thr399Ile no se asocian con la susceptibilidad al SCA en la población mexicana.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Acute Coronary Syndrome/genetics , Polymorphism, Single Nucleotide , /genetics , Mexico , Risk Factors
10.
Arch. cardiol. Méx ; 81(3): 183-187, oct.-sept. 2011. ilus, tab
Article in English | LILACS | ID: lil-685324

ABSTRACT

Objective: To describe the design of a protocol of intracoronary autologous transplant of bone marrow-derived stem cells for acute ST-elevation myocardial infarction (STEMI) and to report the safety of the procedure in the first patients included. Methods: The TRACIA study was implemented following predetermined inclusion and exclusion criteria. The protocol includes procedures such as randomization, bone marrow retrieval, stem cells processing, intracoronary infusion of stem cells in the infarct-related artery, pre-and-post MRI, pre-and-post SPECT with radioisotope ventriculography, and clinical follow-up at 6 months. Results: Eight patients with a diagnosis of acute STEMI and duration of symptoms of <24 hours that were perfused successfully through primary percutaneous coronary intervention (PPCI) with a LVEF of <45% were assigned randomly to two groups (n = 4 each). One group treated with stem cells and the other corresponded to the control group. Neither death, re-infarction, no need for revascularization or thrombosis of the stent were observed at follow-up. Conclusions: The initial experience at the Instituto Nacional de Cardiología Ignacio Chávez in the treatment of acute STEMI by means of autologous transplantation of bone marrow-derived stem cells is encouraging. Implementation was possible in the first eight patients with no complications.


Objetivo: Describir el diseño y la implementación de un protocolo de transplante autólogo intracoronario de células madre derivadas de médula ósea en infarto agudo al miocardio con elevación del ST y reportar la seguridad del procedimiento en los primeros pacientes incluidos. Métodos: El estudio TRACIA se implementó con base en criterios de inclusión y exclusión predeterminados. El protocolo incluye la aleatorización, obtención de médula ósea, procesamiento de células madre, infusión intracoronaria de células madre, RM basal y al seguimiento, SPECT con ventriculografía radioisotópica basal y post-procedimiento, y seguimiento clínico a seis meses. Resultados: Ocho pacientes con diagnóstico de infarto agudo del miocardio con elevación del ST y duración de síntomas <24 horas que fueron reperfundidos exitosamente con angioplastia primaria y con fracción de expulsión <45%, fueron aleatorizados a dos grupos; uno de ellos fue tratado con células madre y el otro grupo permaneció como control. No se observó muerte, re-infarto, necesidad de revascularización o trombosis del Stent durante el seguimiento. Conclusiones: La experiencia inicial en el Instituto Nacional de Cardiología Ignacio Chávez en el tratamiento del infarto agudo del miocardio con elevación del ST mediante trasplante autólogo de células madre derivadas de médula ósea, es alentadora. La implementación sin complicaciones fue posible en los primeros ocho pacientes.


Subject(s)
Female , Humans , Male , Middle Aged , Hematopoietic Stem Cell Transplantation/methods , Myocardial Infarction/surgery , Bone Marrow Cells , Coronary Vessels , Single-Blind Method , Transplantation, Autologous/methods
11.
Arch. cardiol. Méx ; 75(3): 267-278, jul.-sep. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-631900

ABSTRACT

El stent cubierto con membrana se ha reportado como un dispositivo útil para corregir lesiones angiográficas específicas, así como complicaciones potenciales secundarias a procedimientos de intervencionismo coronario. El stent cubierto con membrana de (Jostent-Jomed) está compuesto por una fina capa de politetrafluoroetileno (PTFE) que se localiza entre dos stents metálicos. En esta revisión retrospectiva el stent de PTFE se utilizó en varias lesiones y situaciones angiográficas tanto en arterias coronarias como en injertos venosos. Nuestra experiencia consistió de 17 pacientes que fueron tratados por diferentes indicaciones clínicas y angiográficas: perforación coronaria en dos pacientes (pts), injertos venosos con trombo y cambios degenerativos en ocho (pts), aneurismas coronarios en 4 (pts) y trombo grande refractario a tratamiento habitual en otros 3 casos. Nuestros resultados con el stent de PTFE mostraron una tasa de éxito clínico del 100% sin complicaciones durante la fase hospitalaria y en el seguimiento clínico a 10 ± 3 meses sólo tres pacientes tuvieron algún evento cardíaco adverso mayor. La indicación potencial para el implante del stent de PTFE en injertos venosos todavía no se ha puntualizado; sin embargo a la luz de varios estudios pareciera haber poco beneficio en esta circunstancia. Por otro lado la perforación y el aneurisma coronario parecen ser las indicaciones más recomendables para la aplicación de este dispositivo.


Summary The use of a synthetic membrane-covered stent has been suggested to overcome some specific lesions in coronary arteries and to solve some potential complications that could arise in any procedure of coronary intervention. A synthetic membrane coronary stent graft (JOSTENT-JOMED) is constituted by a membrane of polytetrafluoroethylene (PTFE), fixed between two thin metallic stents. In this clinical review of our laboratory's experience, the Jostent graft was used in several angiographic circumstances in coronary arteries or in vein grafts. Our clinical experience consists of 17 patients that were treated with placement of PTFE stents for different indications: coronary rupture in two patients; thrombus and degenerative vein grafts in eight patients, coronary aneurysms in four patients, and thrombus in coronary arteries in three more. Our clinical results with this device suggest that its implant is feasible and safe with a clinical success of 100% without complications during in-hospital stay; during the clinical 11 ± 3 months follow-up, only three patients exhibited major cardiac events. The indication for PTFE stent in vein grafts with degenerative and thrombus lesions has not been determined yet; however, recently, some randomized trials have shown little benefit in this circumstance. On the other side, coronary vessel rupture and coronary aneurysms are currently the most definitive indications.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Coronary Disease/surgery , Polytetrafluoroethylene , Stents , Aneurysm, Ruptured , Aneurysm, Ruptured/surgery , Coronary Angiography , Coronary Aneurysm , Coronary Aneurysm/surgery , Coronary Disease , Coronary Thrombosis , Coronary Thrombosis/surgery , Feasibility Studies , Follow-Up Studies , Randomized Controlled Trials as Topic , Safety , Time Factors , Treatment Outcome
12.
Arch. cardiol. Méx ; 71(supl.1): S136-S138, ene.-mar. 2001.
Article in Spanish | LILACS | ID: lil-326743

ABSTRACT

La angiogénesis es la formación de nuevos vasos sanguíneos a partir de vasos preexistentes. Este mecanismo requiere de eventos complejos que incluyen moléculas proangiogénicas y antiangiogénicas. Dentro de los principales factores angiogénicos estudiados en la actualidad están el factor de crecimiento fibroblástico (FGF) y el factor de crecimiento del endotelio vascular (VEGF). De manera reciente se han hecho grandes esfuerzos por aplicar estos factores en el tratamiento de la cardiopatía isquémica avanzada y crónica, así como en la enfermedad arterial periférica. En el presente trabajo se revisan los mecanismos angiogénicos, los trabajos experimentales y los estudios clínicos reportados.


Subject(s)
Angiogenesis Inhibitors , Neovascularization, Physiologic/physiology , Peripheral Vascular Diseases/therapy , Myocardial Ischemia/therapy
13.
Arch. Inst. Cardiol. Méx ; 68(6): 462-72, nov.-dic. 1998. tab, ilus
Article in Spanish | LILACS | ID: lil-227597

ABSTRACT

En 249 pacientes con primer infarto del micardio. Grupo 1. Sin trombolítico, n=119; 2. Trombolisis antes de 6 horas, n=80 y grupo 3. Trombolisis entre las 6 y 12 horas, n=50. Se evaluó la presencia de arritmias malignas en el primer año de sobrevida, la variabilidad de la frecuencia cardiaca, el flujo coronario anterógrado (TIMI) y el flujo coronario colateral (1. Pobre: Rentrop, grados 0-2 y 2. Adecuada: Rentrop grado 3). Los grupos 2 y 3 tuvieron mejor flujo TIMI y colateral que el grupo 1 (p<0.001). La banda espectral de alta frecuencia y la relación entre las bandas de baja y alta frecuencia estuvieron más alteradas en el grupo 1 (p<0.05). El análisis de consolidación conjuntiva mostró que los pacientes con TIMI 0-2 y pobre flujo colateral tuvieron mayores epidosios de arritmias malignas que los pacientes con TIMI 0-2 con adecuado flujo colateral (17/138-12.3 por ciento-vs 0/14-0 por ciento-). Los pacientes con TIMI 0-2 y pobre flujo colateral presentaron mayor mortalidad por eventos arrítmicos que los tenían TIMI 3 o TIMI 0-2 con adecuado flujo colateral (x²=7.22, p=0.028), independientemente del tratamiento trombolítico


Subject(s)
Humans , Adult , Middle Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , Coronary Circulation , Coronary Angiography , Coronary Vessels/drug effects , Coronary Vessels/physiopathology , Heart Rate , Rheology , Thrombolytic Therapy , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Myocardial Infarction/therapy , Myocardial Reperfusion , Therapeutic Approaches , Time Factors
14.
Arch. Inst. Cardiol. Méx ; 68(3): 247-52, mayo-jun 1998. tab, ilus
Article in Spanish | LILACS | ID: lil-227569

ABSTRACT

El fenómeno de no-reflujo es una complicación de la reperfución y se ha definido como la ausencia de flujo, no atribuíble a oclusión aguda, disección o espasmo coronario. Las causas y el impacto clínico de este problema no están bien definidos y aunque en la literatura se ha reportado algunas series, no se conoce cual es la incidencia del problema en nuestro medio. Para ello se revisaron 204 angioplastías electivas y 62 primarias; 14 pacientes cumplieron con los criterios de inclusión, 10 con angioplastía primaria y 4 con angioplastía electiva. El problema predominó en el sexo masculino, la edad promedio de 56 años, y fueron la diabetes mellitus y el tabaquismo los factores de riesgo más frecuentes. La arteria involucrada en mayor número de casos fue la descendente anterior (7 pacientes); el tiempo promedio de reperfusión de logró a las 10.6 horas (en los procedimientos primarios) y el tratamiento farmacológico más exitoso fue el verapamil intracoronario. La incidencia global del problema en ambas modalidades de tratamiento fue de 5.2 por ciento (16.12 por ciento en las angiplastías primarias y 1.9 por ciento en los procedimientos electivos). Nuestro estudio demuestra que el fenómeno de no-reflujo es una complicación frecuente y que la incidencia es mayor que la reportada en la literatura


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/statistics & numerical data , Coronary Circulation , Coronary Angiography , Incidence , Myocardial Ischemia/diagnosis , Myocardial Ischemia/epidemiology , Myocardial Ischemia/drug therapy , Treatment Failure , Mexico/epidemiology
15.
Arch. Inst. Cardiol. Méx ; 66(2): 122-8, mar.-abr. 1996. ilus, tab
Article in Spanish | LILACS | ID: lil-180416

ABSTRACT

El infarto agudo del miocardio de origen embólico presenta una incidencia del 5-13 por ciento; se asocia a factores de riesgo de embolia sistémica. El mecanismo del infarto tiene similitud con el infarto de origen aterosclerótico, por lo que es suceptible de tratamiento con trombolisis. Se reportan 3 casos de pacientes con cardiopatía reumática inactiva, coartación de aorta y prótesis valvular mecánica, como probables causas de infarto embólico, de localización posteroinferior con estensión dorsal y a quienes se les administró estreptoquinasa intravenosa. Los pacientes presentaron criterios de reperfusión miocárdica; presentándose en dos, angor post-infarto. El primero presentó reoclusión de la coronaria derecha, llevandolo a colocación de hemoducto venoso. En el segundo se observó la persistencia de trombo en la arteria circunfleja, dejándole con anticoagulación por tres meses y en el tercer caso no se observó lesiones coronarias. Se concluye que la terapia trombolíca con estreptoquinasa en el infarto agudo del miocardio embólico previene la progresión del daño isquémico y favorece la evolución clínica del paciente. Además, debe sospecharse tal enfermedad en pacientes que presentan factores de risgo para embolia sistémica y arterias coronarias normales con obstrucción de un solo vaso


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Coronary Angiography , Embolism/therapy , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Myocardial Infarction/therapy , Myocardial Reperfusion , Thrombolytic Therapy
SELECTION OF CITATIONS